Main Contents begins from here.

Support

HD-PLC Adaptor

Throughput Measurement of BL-PA100

This website introduces the result of data transfer measurement and the measurement environment in UDP and TCP(SmartBit).

UDP Measurement environment and result

Environment

UDP

Measurement Method

  1. Perform throughput test that finds a maximum transmission rate without packet loss.

Result

Packet length(byte) Rate(Mbps)
64 4
512 38
1472 75

TCP Measurement environment and result

Environment

TCP

Measurement Method

  1. The FTP Client gets a file from the FTP Server. The FTP Client puts a file to the FTP Server.
  2. 1. is repeated 5 times and average them.

Specifications

-- FTP Server FTP Client
OS RedHat Linux 9 Windows XP SP2
CPU Pentium4 2GHz Pentium4 2GHz
Memory 512Mbyte 256Mbyte
FTP vsftpd 1.1.3 Command prompt

Result

-- Get(Mbps) Put(Mbps)
Average 44.383 45.730

Banner area begins from here.

HD-PLC Alliance